We support boolean queries, use +,-,<,>,~,* to alter the weighting of terms
The software is used to manually segment and label the 3D point cloud of corn and other crops
test
Open source Python platform for machine learning analysis of adaptive immune receptor repertoires. Supported by ELIXIR Norway.
Rockefeller University Spectroscopy Resource Center Core Facility RESOURCE IS NO LONGER IN SERVICE, documented on February 14, 2022. The core was merged with Rockefeller University Fisher Drug Discovery Resource Center Core Facility. Core provides spectroscopic and calorimetric equipment for use in studies of structure, function and interactions of biological and organic molecules.
GFAP is a major protein of the nervous system localized in astrocytes, large non-neuronal cells which forms part of the blood brain barrier. It is also found in neural stem cells. Antibodies to GFAP are therefore used to identify astrocytes and monitor neural development. Recent work has shown that GFAP leaks into blood, cerebrospinal and other fluids following a variety of damage and disease states. Accordingly sensitive ELISA, MSD, Luminex and Simoa based assays have been developed and are widely utilized in research and clinical contexts. This recombinant human GFAP is an ideal protein standard for such assays.
Human neurofilament light chain (NF-L) is a major neuron specific protein of perikarya and especially in large projection axons . Accordingly antibodies to NF-L are useful to identify neuronal cells and their axonal processes. In addition release of NF-L into blood, cerebrospinal and other fluids reveals ongoing axonal and neuronal loss. This loss may provide useful prognostic and diagnostic information. Sensitive assays for NF-L have therefore been developed. This recombinant human NF-L protein can and has been widely employed as a protein standard for NF-L ELISA, MSD, Luminex, Simoa and other antibody based assays.
Software R package for mapping quantitative trait loci with high dimensional data and multiparent populations. Used for analysis of high dimensional data and complex crosses. Interactive software environment for mapping quantitative trait loci in experimental populations.R/qtl2 software expands scope of R/qtl software package to include multiparent populations derived from more than two founder strains, such as Collaborative Cross and Diversity Outbred mice, heterogeneous stocks, and MAGIC plant populations.
asdas
Collection of very large scale electron microscopy datasets available for on-line browsing. Large scale electron microscopy datasets.
vvvcxcxxcvxcvxcvxvc
Web tool for prediction of full length Long Terminal Repeat retrotransposons. Used for finding LTR retrotransposons in genome sequences.Given DNA sequences, it predicts locations and structure of full length LTR retrotransposons accurately by considering common structural features.
Software tool to detect differential alternative splicing events from RNA-Seq data. Calculates P value and false discovery rate that difference in isoform ratio of gene between two conditions exceeds given user defined threshold. Can automatically detect and analyze alternative splicing events corresponding to all major types of alternative splicing patterns. Handles replicate RNA-Seq data from both paired and unpaired study design.
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on April 12, 2024. Transmission electron research microscope with accelerating voltages of 120 and 200kV and has magnification from 80X to 1,000,000X with resolution line of 0.12nm.
Plate reader for high-throughput, automated dynamic light scattering (DLS) measurements on macromolecular and nanoparticle samples directly in situ in industry-standard 96, 384, or 1536 well microplates, using as little as 1.5 �L of sample and 5 seconds acquisition time per well.
Microprocessor controlled, gassed, humidified, benchtop incubator intended for use in cell culture. The device is designed to maintain temperature accurately at a temperature between 35 and 40 degrees Celsius and gas flow within the range of 15 to 25 ml/min.
High performance liquid chromatographic system with quaternary, low pressure mixing pump and inline vacuum degassing. It has wavelengths of 190 to 800 nm and flow rates from 50 uL per min to 5 mL per min with 2.1 mm ID columns and larger. Autosampler has maximum capacity of 120 vials (12x32, 2 mL) with programmable temperature control from 4 to 40C. Heated column compartment provides temperatures from 5 degrees above ambient to 65C.
Variable mode imager that produces digital images of radioactive, fluorescent, or chemiluminescent samples and contains three internal lasers (blue, green, and red)
Acrylic heated bath circulator that provides efficient heating from ambient plus 13C to a maximum of 80C, with maximum bath volume of 12 liters and a voltage of 100 V.
Water bath with a capacity of 15L that supports a range of sensitive life science and is designed specifically for applications that require your samples to be incubated in a controlled atmosphere.
Triple stage quadrupole mass spectrometer for low level quantitation and has mass range of mass per charge 10 to 1800 mass per charge. Laboratory room temperature must be maintained between 18 to 27 C and cannot change by more than 5 C.