Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
Inverted fluorescence tissue culture microscope capable of imaging specimens in brightfield, darkfield, phase contrast, Hoffman modulation contrast, fluorescence, and differential interference contrast modes.TIRFM-IX illuminator is this microscope accessory which attaches to the rear lamphouse port and contains FC connector for external laser source and port for mercury or xenon lamp housing.
Proper citation: Olympus IX70 Inverted Fluorescence Microscope (RRID:SCR_018604) Copy
http://tools.thermofisher.com/content/sfs/brochures/PS-64079-MS-TSQ-Quantiva-PS64079-EN.pdf
Triple stage quadrupole mass spectrometer for low level quantitation and has mass range of mass per charge 10 to 1800 mass per charge. Laboratory room temperature must be maintained between 18 to 27 C and cannot change by more than 5 C.
Proper citation: Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer (RRID:SCR_018650) Copy
https://www.blockscientific.com/roche-integra-400-plus#attr=
COBAS INTEGRA 400 plus analyzer is a chemistry analyzer with a broad test menu comprises over 120 assays and applications that consolidate clinical chemistry with specific proteins, therapeutic drug monitoring and drug abuse testing.The Cobas 400 analyzer is best for laboratories running up to 400 samples per day. This compact tabletop analyzer offers maximum versatility to improve efficiency and reduce costs. It uses the convenient cobas c pack reagent format, which standardizes patient results across integrated laboratory networks.
Proper citation: Roche Cobas Integra 400 Plus Chemistry Analyzer (RRID:SCR_018629) Copy
https://www.marshallscientific.com/Thermo-Shandon-Cytospin-3-Centrifuge-p/th-cyto3.htm
Thermo Shandon Cytospin 3 is low speed centrifuge used to separate and deposit monolayer of cells on slides while maintaining cellular integrity.Centrifuge has speed range between 200 and 2000 RPM, and has holding capacity of up to 24 samples in 12 chambers.
Proper citation: Shandon Cytospin 3 Centrifuge (RRID:SCR_018628) Copy
Hybrid quadrupole time of flight mass spectrometer with MS mass range 6,000 and 40,000 m z designed proteomics, drug discovery, metabolomics, and drug development. Instrument used with Analyst QS software.
Proper citation: SCIEX QStar XL Mass Spectrometer (RRID:SCR_018627) Copy
https://www.labx.com/item/rigaku-x-stream-2000-cryogenic-crystal-cooler-system/LV40211010
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on March 11,2024. Self contained cryo freezing system designed cooling crystals with range of negative 80C to 4C. It produces nitrogen, which is then cooled to negative 196C, and then rewarmed to desired temperature.
Proper citation: Rigaku X-Stream 2000 Cryo-Freezing System (RRID:SCR_018633) Copy
https://www.fishersci.com/shop/products/shandon-finesse-325-manual-microtome/p-4529936
Manual microtome with flywheel for routine paraffin sectioning. Can cut 1 to 30 um speciment thickness, and specimen tilt or orientation is plus or minus 5 degrees using X Y micro adjustment.Has quick release cassette clamp and x-y orientation head supplied as standard, disposable blades or standard microtome knives.
Proper citation: Shandon 325 Manual Microtome (RRID:SCR_018632) Copy
Microplate reader that can read one sample or up to 384 in single plate read using any standard cuvette, 12 x 75 mm test tube, or 96 or 384 well microplate. It can run standard spectrophotometer and microplate reader applications.
Proper citation: Molecular Devices Spectramax Plus384 Microplate Reader (RRID:SCR_018598) Copy
https://www.milabs.com/u-spect/
Nuclear imager for quantitative 3D functional imaging of SPECT tracers down to 0.12 mm ex vivo and 0.25 mm in vivo. Used for quantitative sub mm imaging of higher energy and theranostic isotopes such as 131I, 188Re, 213Bi, 225Ac, and 223Ra.
Proper citation: MILabs U Spect Nuclear Imager (RRID:SCR_018597) Copy
https://www.sutter.com/manuals/P-97-DOM_OpMan.pdf
Pipette puller that fabricates pipettes for use in intracellular recording, patch clamping, transferring ICSI, ES Cells , microinjection, aspiration, and microperfusion. P-97 puller can indirectly sense viscosity of glass, giving the ability to pull pipettes from all glasses except quartz. Even difficult to pull formulations, such as aluminosilicate glasses, are handled with relative ease.
Proper citation: Sutter P-97/PC Pipette Puller (RRID:SCR_018636) Copy
Automated cell sorter that has microfluidics sorting chip integrated with six fluorescence detectors and up to four collinear excitation lasers of 488 nm, 405 nm, 561 nm and 638 nm.
Proper citation: Sony SH800Z Cell Sorter (RRID:SCR_018635) Copy
Siemens Dade Behring BN II Nephelometer is leading fully automated system for plasma protein determinations. BN II systems offer advanced nephelometric technology that provides performance in plasma protein analysis. This instrument's menu covers assays, which support various clinical tests including cardiac risk assessment, kidney diseases and nutritional assessment. markers such as Cystatin C and Carbohydrate-Deficient Transferrin (CDT) are also supported. Other features of the Dade Behring BN II Nephelometer include rapid processing, easy operation and random-access mode. The nephelometer also permits users to put up to 100 samples on board, making it best for mid to high-volume processing.
Proper citation: Siemens Dade Behring BNII Nephelometer System (RRID:SCR_018634) Copy
Benchtop manager cell sorter for cell isolation in automated workflows. Sorts cells directly from whole blood or bone marrow without density gradient centrifugation or erythrocyte lysis.
Proper citation: Miltenyi AutoMACS Magnetic Cell Sorter (RRID:SCR_018596) Copy
https://ctac.mbi.ufl.edu/histology-self-serve/microm-cryostat/
Electronic microtome cryostat upright standing with open top working area that can cut temperature to negative 35 degrees Celsius. Equipped with automatic 24 hour defroster with interrupt key and handwheel brake.Provides protection for knife and specimen as it retracts specimen at the end of the cut. Motorized coarse feed system allows sample to be moved forward and backward.Two knife carriers are available. Standard knife carrier is for knives to be easily clamped in place and adjusted, and the disposable blade holder EC for high- and low-profile blades.
Proper citation: Microm HM505E Cryostat (RRID:SCR_018595) Copy
Differential scanning calorimeter for study of samples in solution. It measures intramolecular stability of proteins, nucleic acids, oligomeric proteins, nucleic acid duplexes, lipid and detergent micellar system.
Proper citation: Microcal VPViewerTM Differential Scanning Calorimeter VP--DSC (RRID:SCR_018594) Copy
https://www.tissuevision.com/overview
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on March 11,2024. Whole organ serial two photon tomography imaging platform that allows imaging of whole fixed organs based on high speed two photon microscopy TPM and integrated tissue sectioning.
Proper citation: TissueVision TissueCyte 1000 Photon Imaging System (RRID:SCR_018639) Copy
https://assets.thermofisher.com/TFS-Assets/LED/Specification-Sheets/Hydra_II_Spec_Sheet_FINAL.pdf
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on February 22,2024. Bench top 96 or 384 channel liquid handler capable of automating pipetting tasks, including low volume and viscous sample transfers. It utilizes syringe based technology to dispense solutions.
Proper citation: Thermo Scientific Hydra II Microdispenser (RRID:SCR_018638) Copy
https://www.physicsforums.com/attachments/wh-ifu-minc-2_v2-pdf.41467/
Benchtop incubator microprocessor controlled, gassed, humidified, incubator intended for use in cell culture. It is designed to maintain temperature between 35 and 40 degrees celsius and gas flow within range of 15 to 25 ml min.
Proper citation: WilliamA Cook Australia K-MINC-1000 Benchtop Incubator (RRID:SCR_018644) Copy
https://www.tousimis.com/critical_point_dryers/detail.html?Pid=8780C
Critical point dryer with wafer holders that allow automatic anti stiction processing up to 5 pieces of either 100mm, 75mm, 50mm wafers or 10mm square die per process run. All internal surfaces are inert to CO2 and ultra pure alcohols.
Proper citation: Tousimis Autosamdri 815B Critical Point Dryer (RRID:SCR_018642) Copy
http://www.labwrench.com/?equipment.view/equipmentNo/9101/Wyatt-Technology/DynaPro-Plate-Reader-II/
Plate reader that automates dynamic light scattering measurements on macromolecular and nanoparticle samples in situ in 96, 384, or 1536 well microplates. It screens for particle size, thermal stability, aggregation temperature tonset, colloidal stability via diffusion interaction parameter kD or D1, and viscosity of protein solutions.
Proper citation: Wyatt Dynapro II Plate Reader (RRID:SCR_018648) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.