Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
https://mass-spec.stanford.edu/instruments
Bruker micrOTOF-Q II is benchtop Q-Tof mass spectrometer, applied to applications such as small molecule accurate mass determination, intact protein analysis including antibodies, peptide mapping, and other custom projects. This system is operated with Agilent 1260 UPLC and includes inline diode array detector and ESI source.
Proper citation: Bruker micrOTOF-Q II LC/MS system (RRID:SCR_018697) Copy
https://mass-spec.stanford.edu/instruments
Microflex LRF mass spectrometer is specialized for protein, peptide, and polymer analysis. This MALDI-TOF instrument can be operated in linear mode for high mass accuracy characterization, or in reflector mode to achieve enhanced resolution.
Proper citation: Bruker Microflex MALDI TOF mass spectrometer (RRID:SCR_018696) Copy
Luminometer combines instrumentation and software for uses includinh bioluminescent assays, protocols and support. You can measure flash or glow-type luminescence, have two fluorescent modules available, and it accommodates 1.5ml microcentrifuge tubes and 35mm petri dishes, with optional 12mm × 50mm test tube adapter. Measure light output from liquid and solid samples; no minimum volume requirements. The GloMax 20/20 blends user-friendly operation and a small footprint.This Instrument Was Retired September 1, 2023. Accessories and service available until September 1, 2028.
Proper citation: Promega GloMax 20/20 Luminometer (RRID:SCR_018613) Copy
https://mass-spec.stanford.edu/instruments
LTQ-Orbitrap Elite mass spectrometer with Waters nanoAcquity system. Used for proteomic applications.
Proper citation: Thermo LTQ-Orbitrap Elite nano LC/MS system (RRID:SCR_018694) Copy
https://www.qiagen.com/us/spotlight-pages/ias/qiacube-classic-resource-page/
Purification system that performs fully automated purification of nucleic acids and proteins in molecular biology applications.
Proper citation: Qiagen QIAcube Classic (RRID:SCR_018618) Copy
https://www.perkinelmer.com/product/zephyr-ngs-workstation-133750
Benchtop liquid handler designed to automate construction of 48 to 96 next generation sequencing libraries per day.
Proper citation: Perkin Elmer Zephy G3 NGS liquid handler (RRID:SCR_018616) Copy
PCR Setup Robot. Compact benchtop instrument for setup of PCR experiments with setup and automatic calculation of all mixes, eliminating the need to program pipetting steps.
Proper citation: Qiagen QIAgility (RRID:SCR_018622) Copy
https://www.perkinelmer.com/product/ivis-instrument-spectrum-120v-andor-c-124262
In vivo imaging system that combines two dimensional and three dimensional optical tomography in one platform.The system uses leading optical technology for preclinical imaging research and development best for non-invasive longitudinal monitoring of disease progression, cell trafficking and gene expression patterns in living animals.
Proper citation: Perkin Elmer IVIS Spectrum In Vivo Imaging System (RRID:SCR_018621) Copy
Sequencer that uses pyrosequencing technology for real time, sequence based detection, quantification of sequence variants, and epigenetic methylation. Used for analysis of CpG methylation, SNPs, insertion deletions, STRs, variable gene copy number, and for microbial identification and resistance typing.
Proper citation: Qiagen Pyromark Q24 Sequencer (RRID:SCR_018620) Copy
Genetic analyzer that automates electrophoresis analysis of your DNA and RNA samples.
Proper citation: Qiagen QIAxcel Genetic Analyzer (RRID:SCR_018624) Copy
RNA and DNA purification analyzer that disrupts biological samples through high speed shaking in plastic tubes with stainless steel, tungsten carbide, or glass beads.Can analyze up to 48 or 192 samples at the same time.
Proper citation: Qiagen Tissue Lyser II (RRID:SCR_018623) Copy
Integrated software and instrument system for performance in cell-based screening and analysis.
Proper citation: Cellinsight CX7 High-Content Screening Platform (RRID:SCR_018706) Copy
https://mass-spec.stanford.edu/instruments
Micromass (now Waters) Quattro Premier triple quadrupole operates with Agilent 1100 HPLC and specializes in quantitative work and selective of targeted analytes including metabolites and other small molecules, and peptides from complex matrices such as serum, tissue, cell culture, and other biological sources.
Proper citation: Waters Quattro Premier LC/MS system (RRID:SCR_018705) Copy
https://mass-spec.stanford.edu/instruments
Triple quad mass spectrometer for quantitative work and selective assays of targeted analytes. Can analyze metabolites, peptides from matrices such as serum, tissue, cell culture, and other biological sources.
Proper citation: Thermo Vantage LC/MS mass spectrometer (RRID:SCR_018704) Copy
Confocal microscope covers broad range of requirements in confocal and multiphoton imaging with array of scan speeds at highest resolution., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: Leica TCS SP5 II microscope (RRID:SCR_018714) Copy
https://www.leica-microsystems.com/products/light-microscopes/p/leica-dmi6000-b/
Inverted microscope for biomedical research. Offers Differential Interference Contrast for relief imaging of specimens with varying indices of refraction. Used for fluorescence, live cell, time-lapse imaging, high-speed multi-fluorescence optical sectioning, and micromanipulation. Features automated contrast and illumination manager, motorized Z focus, parfocality function, automatic brightness and diaphragm adjustment, and many other automated functions that provide convenience and reproducible results. Archived Product. Replaced by DMi8 S.
Proper citation: Leica DMI6000 B inverted microscope (RRID:SCR_018713) Copy
Inverted fluorescence tissue culture microscope capable of imaging specimens in brightfield, darkfield, phase contrast, Hoffman modulation contrast, fluorescence, and differential interference contrast modes.TIRFM-IX illuminator is this microscope accessory which attaches to the rear lamphouse port and contains FC connector for external laser source and port for mercury or xenon lamp housing.
Proper citation: Olympus IX70 Inverted Fluorescence Microscope (RRID:SCR_018604) Copy
http://tools.thermofisher.com/content/sfs/brochures/PS-64079-MS-TSQ-Quantiva-PS64079-EN.pdf
Triple stage quadrupole mass spectrometer for low level quantitation and has mass range of mass per charge 10 to 1800 mass per charge. Laboratory room temperature must be maintained between 18 to 27 C and cannot change by more than 5 C.
Proper citation: Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer (RRID:SCR_018650) Copy
https://mass-spec.stanford.edu/instruments
Thermo Exactive benchtop Orbitrap operates with Waters Acquity UPLC and generates high resolution, high mass accuracy full MS data. Available to advanced open access users for reversed phase and HILIC LC/MS applications.
Proper citation: Thermo Exactive Orbitrap LC/MS system (RRID:SCR_018700) Copy
https://www.blockscientific.com/roche-integra-400-plus#attr=
COBAS INTEGRA 400 plus analyzer is a chemistry analyzer with a broad test menu comprises over 120 assays and applications that consolidate clinical chemistry with specific proteins, therapeutic drug monitoring and drug abuse testing.The Cobas 400 analyzer is best for laboratories running up to 400 samples per day. This compact tabletop analyzer offers maximum versatility to improve efficiency and reduce costs. It uses the convenient cobas c pack reagent format, which standardizes patient results across integrated laboratory networks.
Proper citation: Roche Cobas Integra 400 Plus Chemistry Analyzer (RRID:SCR_018629) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.